Jubaili Bros Marapco Generator

MARAPCO DIESEL GENERATORS

Backed by over 20 Years of experience as a diesel generator supplier, Marapco offers a wide range of Diesel Generators, powered by Perkins and MTU engines and coupled with alternators from Leroy-Somer, ranging up to 3300 KVA.

With a team of highly qualified generator manufacturer professionals, Marapco constantly strives to incorporate the latest technology to improve the efficiency and performance of Marapco Generators. These Generating Sets are customized to cater to the diversified needs of individuals, consumers and corporate world across a range of industries.

Marapco branded Diesel Generators use Perkins and MTU Engines and range from 12.5 KVA up to 3300 KVA. These generators are designed, developed, manufactured and tested to the highest international standards such as: ISO8528, BS4999, BS5514, IEC60034, VDE0530.

Marapco generators can withstand diverse operational conditions, making them a reliable source of Power.

Depending on specific requirements, Marapco Diesel Generators can be customized with a variety of performance options and ancillary equipment, ensuring outstanding cost effective power solutions.

Marapco generators are covered with one year Warranty in line with Perkins / MTU and Leroy Somer warranty against manufacturing defects, as per our warranty terms and conditions. Marapco is an official O.E.M. for Perkins Engines and spare parts.

Marapco has been the preferred supplier of made in UK diesel generators for two decades and looks forward to continuing this trend. Please feel free to contact our sales team for a highly competitive and customized solution to meet your needs – Marapco is ‘Your Partner in Power’.

–>

Generating SetPerkins EngineLeroy Somer
Alternator
Rating
RPMkVAkW
PrimeStandbyPrimeStandby
MP12.5-MP14E403A-15GLSA40VS2 | TAL040C150012.514.010.011.2
MP15-MP16.5E403A-15G2LSA40S3 | TAL040D150015.016.512.013.2
MP20-MP22E404A-22G1LSA40M5 | TAL040F150020.022.016.017.6
MP30-MP33E1103A-33GLSA42.3VS3 | TAL042C150030.033.024.026.4
MP45-MP50E1103A-33TG1LSA42.3M7 | TAL042F150045.050.036.040.0
MP60-MP66E1103A-33TG2LSA42.3L9 | TAL042H150060.066.048.052.8
MP80-MP88E1104A-44TG2LSA44.3S3 | TAL044B150080.088.064.070.0
MP100-MP110E1104C-44TAG2LSA44.3S5 | TAL044D1500100.0110.080.088.0
MP135-MP150E1106A-70TG1LSA44.3M8 | TAL044H1500135.0150.0108.0120.0
MP150-MP165E1106A-70TAG2LSA44.3L10 | TAL044J1500150.0165.0120.0132.0
MP180-MP200E1106A-70TAG3LSA46.3S2 | TAL046A1500180.0200.0160.0176.0
MP200-MP220E1106A-70TAG4LSA46.3S3 | TAL046B1500200.0220.0160.0176.0
MP200-MP220E1206A-E70TTAG1LSA46.3S3 | TAL046B1500200.0220.0160.0176.0
MP230-MP250E1206A-E70TTAG2LSA46.3S4 | TAL056C1500225.0250.0180.0200.0
MP250-MP275E1206A-E70TTAG3LSA46.3S5 | TAL046D1500250.0275.0200.0220.0
MP300-MP330E1506A-E88TAG5LSA 46.3M8 | TAL046F1500300.0330.0240.0264.0
MP350-MP400E2206A-E13TAG2SA46.3L11 | TAL046H1500350.0400.0280.0320.0
MP400-MP450E2206A-E13TAG3LSA47.2S4 | TAL047A1500400.0450.0320.0360.0
MP450-MP500E2506A-E15TAG1LSA47.2S5 | TAL047B1500450.0500.0360.0400.0
MP500-MP550E2506A-E15TAG2LSA47.2M7 | TAL047C1500500.0550.0400.0440.0
MP600-MP660E2806A-E18TAG1ALSA47.2L9 | TAL047E1500600.0660.0480.0528.0
MP650-MP700E2806A-E18TAG2LSA49.3S4 | TAL047F1500650.0700.0520.0560.0
MP725-MP800E4012-46TWG2ALSA49.3M6 | TAL049B1500725.0800.0580.0640.0
MP800-MP900E4006-23TAG3ALSA49.3M8 | TAL049C1500800.0900.0640.0720.0
MP1000-MP1100E4008-30TAG2LSA49.3L10 | TAL049E15001000.01100.0800.0880.0
MP1250-MP1375E4012-46TWG2ALSA50.2M615001250.01375.01000.01100.0
MP1350-MP1500E4012-46TAG1ALSA50.2L715001350.01500.01080.01200.0
MP1500-MP1650E4012-46TAG2ALSA50.2L815001500.01650.01200.01320.0
MP1710-MP1880E4012-46TAG3ALSA52.3S515001710.01880.01368.01504.0
MP1850-MP2000E4016-61TRG1LSA52.3S515001850.02000.01480.01600.0
MP2000-MP2200E4016TAG2ALSA52.3S615002000.02200.01600.01760.0
MP2000-MP2250E4016-61TRG2LSA52.3L915002000.02250.01600.01800.0
MP2250-MP2500E4016-61TRG3LSA52.3L915002250.02500.01800.02000.0
04/2020
Generating SetPerkins EngineLeroy Somer
Alternator
Rating
RPMkVAkW
PrimeStandbyPrimeStandby
MP14.5-MP16E403D-15GLSA40VS2180014.516.011.612.8
MP17.5-19.5E403A-15G2LSA40S3180017.519.514.015.6
MP23-MP26E404D-22GLSA40M5180023.026.018.420.8
MP34-MP37.5E1103A-33GLSA42.3VS2180034.037.527.030.0
MP53-MP59E1103A-33TG1LSA42.3M7180053.059.042.447.2
MP69-MP76E1103A-33TG2LSA42.3L9180069.076.055.061.0
MP76-MP84E1104A-44TG1LSA44.3S2180076.084.061.067.0
MP91-MP100E1104A-44TG2LSA44.3S3180091.0100.072.880.0
MP114-MP127E1104C-44TAG2LSA44.3S51800114.0127.091.2101.6
MP152-MP169E1106A-70TG1LSA44.3M81800152.0169.0121.6135.2
MP169-MP188E1106A-70TAG2LSA44.3L101800169.0188.0135.2150.4
MP197-MP219E1106A-70TAG3LSA44.3VL131800197.0219.0157.6175.2
MP225-MP250E1206A-E70TTAG1LSA46.3S71800225.0250.0180.0200.0
MP250-MP273E11506A-E88TAG1LSA46.3S41800250.0275.0200.0220.0
MP290-MP320E1506A-E88TAG3LSA46.2M71800290.0320.0232.0256.0
MP350-MP390E1506A-E88TAG5LSA46.3L101800350.0390.0280.0312.0
MP400-MP438E2206A-E13TAG5LSA46.3L111800400.0438.0320.0350.4
MP438-MP500E2206A-E13TAG6LSA47.2VS21800438.0500.0350.4400.0
MP513-MP563E2506A-E15TAG3LSA47.2S51800513.0563.0410.4450.4
MP569-MP624E2506A-E15TAG4LSA47.2M71800569.0624.0455.2499.2
MP625-MP687E2806A-E18TAG1ALSA47.2M71800625.0687.0500.0549.6
MP681-MP750E2806A-E18TAG3LSA47.2L91800681.0750.0544.8600.0
MP750-MP825E4006-23TAG2ALSA49.3S41800750.0825.0600.0660.0
MP850-MP944E4006-23TAG3ALSA49.3M81800850.0944.0680.0755.0
MP1000-MP1100E4008TAG2LSA49.3L918001000.01100.0800.0880.0
MP1250-MP1375E4012-46TWG2ALSA50.2M618001250.01375.01000.01100.0
MP1350-MP1500E4012-46TAG1ALSA50.2L818001350.01500.01080.01200.0
MP1500-MP1650E4012-46TWG4ALSA50.2L818001500.01600.01200.01280.0
06/2020
Generating SetPerkins EngineLeroy Somer
Alternator
Rating
RPMkVAkW
PrimeStandbyPrimeStandby
MP13-MP14.5E403A-15G1TAL 040 C150013.014.510.011.2
MP15-MP16.5E403A-15G2TAL 040 D150015.016.512.013.2
MP20-MP22E404A-22G1TAL 040 F150020.022.016.617.6
MP27-MP30E1103A-33GTAL 042 B150027.030.021.624.0
MP30-MP33E1103A-33GLSA 42.3 VS3150030.033.024.026.4
MP45-MP50E1103A-33TG1TAL 042 F150045.049.636.039.7
MP60-MP66E1103A-33TG2TAL 042 H150060.066.048.052.8
MP80-MP88E1104A-44TG2TAL 044 B150080.088.064.070.4
MP100-MP110E1104C-44TAG2TAL 044 D1500100.0110.080.088.0
MP135-MP150E1106A-70TG1TAL 044 H1500135.0150.0108.0120.0
MP150-MP165E1106A-70TAG2TAL 044 J1500150.0165.0120.0132.0
MP200-MP220E1106A-70TAG4LSA 46.2 L61500200.0220.0160.0176.6
MP250-MP275E1506A-E88TAG3LSA 46.2 L61500250.0275.0200.0220.0
MP300-MP330E1606-E93TAG5LSA 46.2V L121500300.0330.0240.0264.0
MP350-MP400E2206A-E13TAG2LSA 47.2 VS21500350.0400.0280.0320.0
MP400-MP450E2206A-E13TAG3LSA 47.2 S41500400.0450.0320.0360.0
MP500-MP550E2506A-E15TAG2LSA 47.2 M71500500.0550.0400.0440.0
MP650-MP700E2806A-E18TAG2LSA 49.1 S41500650.0700.0520.0560.0
MP800-MP900E4006-23TAG3ALSA 49.1 M751500800.0900.0640.0720.0
1810/2017
  • Perkins Powered – 3 Phase, 480V, 60 Hz
  • Marapco Generators are also available in 60 Hz on demand

Nigeria Marapco Diesel Generators (up to 800 KVA) are exclusively for Nigerian Market Only

Generating SetMTU EngineLeroy Somer
Alternator
Rating
RPMkVAkVA
PrimeStandby
MT100016V2000G26FLSA 50.2 M615001000.01100.0
MT113516V2000G36FLSA 50.2 M615001135.01250.0
MT125018V2000G26FLSA 50.2 L715001250.01400.0
MT150012V4000G23LSA 51.2 S5515001500.01650.0
MT165012V4000G23LSA 51.2 S5515001650.01800.0
MT180012V4000G63LSA 51.2 M6015001800.02000.0
MT210016V4000G23LSA 51.2 VL9015002100.02300.0
MT230016V4000G63LSA 51.2 VL9515002300.02550.0
MT255020V4000G23LSA 53.1 M8015002550.02850.0
MT280020V4000G63LSA 54 M7515002800.03100.0
MT300020V4000G63LLSA 54 M7515003000.03300.0
1610/2017

With the comprehensive choice of power outputs from 1000 to 3000kVA (50 Hz) the new MTU powered generator sets with Series offer the optimum solution for various applications. The State-of-the-art common rail technology sets benchmarks in respect of the efficiency. Verified product design, quality, and performance integrity and cutting-edge emissions control.

TESTIMONIALS